7809LP A/D Converter, 16-bit, Serial, Single Event Latchup-protected

   

7809LP Information
- Product Datasheet
- Product Flow

- Back to Data Conversion

Features

  • RAD-PAK® radiation-hardened against natural space radiation
  • Total dose hardness:
    • > 100 krad (Si), depending upon space mission
  • Latch-up Protection Technology (LPTTM)
  • SEL converted into a reset
    • Rate based on cross section and mission
  • Same footprint as ADS7809
  • Package: 24 pin RAD-PAK flat package
  • 100 kHz min sampling rate
  • ±10 V and 0 V to 5 V input range
  • Advanced CMOS technology
    • DNL: 16-bits "No Missing Codes"
    • 83 dB min SINAD with 20 kHz input
    • Single +5 V supply operation
    • Utilizes internal or external reference
    • Serial output
    • Power dissipation: 132 mW max

Description

Maxwell Technologies’ 7809LP high-speed 16-bit analog to digital converter features a greater than 100 kilorad (Si) total dose tolerance depending upon space mission. Using Maxwell’s radiation-hardened RAD-PAK® packaging technology, the 7809LP has the same footprint as ADS7809 and is latchup protected by Maxwell Technologies’ Latchup Protection Technology (LPTTM). It is a 24 pin, 16-bit sampling analog-to-digital converter using state-of-the-art CMOS structures.

The 7809LP contains a 16-bit capacitor based SAR A/D with S/H, reference, clock, interface for microprocessor use, and serial output drivers. The 7809LP is specified at a 100kHz sampling rate, and guaranteed over the full temperature range. Laser trimmed scaling resistors provide various input ranges include ±10 V and 0 to 5 V, while the innovative design allows operation from a single +5 V supply, with power dissipation of under 132 mW.

Maxwell Technologies' patented RAD-PAK packaging technology incorporates radiation shielding in the microcircuit package. It eliminates the need for box shielding while providing the required radiation shielding for a lifetime in orbit or space mission. In a GEO orbit, RAD-PAK provides greater than 100 krad (Si) radiation dose tolerance. This product is available with screening up to Class K.